Flow Cytometry - Equipment

Analysis Flow Cytometers

37 flow_cytometry LSR Fortessa BD
  • measurement of 20 parameters: 18 fluorescence detectors, FSC and SSC
  • 5 lasers: UV (355nm), Violet (405nm), Blue (488nm), Yellow-Green (561nm), Red (640nm)
  • optional: fully automated and rapid sample acquisition (HTS)
  • Instrument Configuration
CRTD 3rd floor south, room 3.113 0351-458-82368 You must either specify a string src or a File object. https://techpool.biotec.tu-dresden.de/schedule.php

LSR Fortessa (BD)

  • measurement of 20 parameters: 18 fluorescence detectors, FSC and SSC
  • 5 lasers: UV (355nm), Violet (405nm), Blue (488nm), Yellow-Green (561nm), Red (640nm)
  • optional: fully automated and rapid sample acquisition (HTS)
  • Instrument Configuration
CRTD 3rd floor south, room 3.113
38 flow_cytometry LSR II BD
  • measurement of 19 parameters: 17 fluorescence detectors, FSC and SSC
  • 4 lasers: UV (355nm), Violet (405nm), Blue (488nm), Red (635nm)
  • optional: fully automated and rapid sample acquisition (HTS)
  • Instrument Configuration
CRTD 1st floor north, room 1.229 0351-458-82138 You must either specify a string src or a File object. https://techpool.biotec.tu-dresden.de/schedule.php

LSR II (BD)

  • measurement of 19 parameters: 17 fluorescence detectors, FSC and SSC
  • 4 lasers: UV (355nm), Violet (405nm), Blue (488nm), Red (635nm)
  • optional: fully automated and rapid sample acquisition (HTS)
  • Instrument Configuration
CRTD 1st floor north, room 1.229
39 flow_cytometry LSR II BD
  • measurement of 10 parameters: 8 fluorescence detectors, FSC and SSC
  • 3 lasers: Violet (405nm), Blue (488nm), Red (640nm)
  • optional: fully automated and rapid sample acquisition (HTS)
  • Instrument Configuration
CRTD 3rd floor south, room 3.113 0351-458-82368 You must either specify a string src or a File object. https://techpool.biotec.tu-dresden.de/schedule.php

LSR II (BD)

  • measurement of 10 parameters: 8 fluorescence detectors, FSC and SSC
  • 3 lasers: Violet (405nm), Blue (488nm), Red (640nm)
  • optional: fully automated and rapid sample acquisition (HTS)
  • Instrument Configuration
CRTD 3rd floor south, room 3.113
40 flow_cytometry FACSCanto II SORP BD
  • measurement of 10 parameters: 8 fluorescence detectors, FSC and SSC
  • 3 lasers: Blue (488nm), Yellow-Green (561nm), Red (635nm)
  • optional: fully automated and rapid sample acquisition (HTS)
  • Instrument Configuration
CRTD 3rd floor south, room 3.113 0351-458-82368 You must either specify a string src or a File object. https://techpool.biotec.tu-dresden.de/schedule.php

FACSCanto II SORP (BD)

  • measurement of 10 parameters: 8 fluorescence detectors, FSC and SSC
  • 3 lasers: Blue (488nm), Yellow-Green (561nm), Red (635nm)
  • optional: fully automated and rapid sample acquisition (HTS)
  • Instrument Configuration
CRTD 3rd floor south, room 3.113
41 flow_cytometry MACSQuant Miltenyi
  • measurement of 9 parameters: 7 fluorescence detectors, FSC and SSC
  • 3 lasers: Violet (405nm), Blue (488nm), Red (635nm)
  • automated sample acquisition (tube rack or well plates)
  • integrated magnetic pre-enrichment option
  • Instrument Configuration
CRTD 1st floor north, room 1.229 0351-458-82138 You must either specify a string src or a File object. https://techpool.biotec.tu-dresden.de/schedule.php

MACSQuant (Miltenyi)

  • measurement of 9 parameters: 7 fluorescence detectors, FSC and SSC
  • 3 lasers: Violet (405nm), Blue (488nm), Red (635nm)
  • automated sample acquisition (tube rack or well plates)
  • integrated magnetic pre-enrichment option
  • Instrument Configuration
CRTD 1st floor north, room 1.229
42 flow_cytometry FACSCalibur BD
  • measurement of 6 parameters: 4 fluorescence detectors, FSC and SSC
  • 2 lasers: Blue (488nm), Red (635nm)
  • Instrument Configuration
CRTD 3rd floor south, room 3.112 0351-458-82368 You must either specify a string src or a File object. https://techpool.biotec.tu-dresden.de/schedule.php

FACSCalibur (BD)

  • measurement of 6 parameters: 4 fluorescence detectors, FSC and SSC
  • 2 lasers: Blue (488nm), Red (635nm)
  • Instrument Configuration
CRTD 3rd floor south, room 3.112

Cell Sorters

44 flow_cytometry FACSAria III BD
  • measurement of 18 parameters: 16 fluorescence detectors, FSC and SSC
  • 4 lasers: Violet (405nm), Blue (488nm), Yellow-Green (561nm), Red (633nm)
  • sorting into different tubes, well plates and onto microscope slides
  • Instrument Configuration
CRTD 3rd floor south, room 3.113 0351-458-82368 You must either specify a string src or a File object. https://techpool.biotec.tu-dresden.de/schedule.php

FACSAria III (BD)

  • measurement of 18 parameters: 16 fluorescence detectors, FSC and SSC
  • 4 lasers: Violet (405nm), Blue (488nm), Yellow-Green (561nm), Red (633nm)
  • sorting into different tubes, well plates and onto microscope slides
  • Instrument Configuration
CRTD 3rd floor south, room 3.113
45 flow_cytometry FACSAria II SORP BD
  • measurement of 16 parameters: 14 fluorescence detectors, FSC and SSC
  • 5 lasers: UV (355nm), Violet (405nm), Blue (488nm), Yellow-Green (561nm), Red (633nm)
  • sorting into different tubes, well plates and onto microscope slides
  • Instrument Configuration
CRTD 1st floor north, room 1.229 0351-458-82138 You must either specify a string src or a File object. https://techpool.biotec.tu-dresden.de/schedule.php

FACSAria II SORP (BD)

  • measurement of 16 parameters: 14 fluorescence detectors, FSC and SSC
  • 5 lasers: UV (355nm), Violet (405nm), Blue (488nm), Yellow-Green (561nm), Red (633nm)
  • sorting into different tubes, well plates and onto microscope slides
  • Instrument Configuration
CRTD 1st floor north, room 1.229

Imaging Flow Cytometry

43 flow_cytometry ImageStreamX Mark II Amnis/Millipore
  • the Imaging Flow Cytometer combines high throughput, quantitative and sensitive single cell analysis of a Flow Cytometer with microscopic imaging and spatial resolution
  • 6 lasers: Violet (405nm), Blue (488nm), YellowGreen (561nm), Orange (592nm), Red (642nm), farRed (785nm)
  • measurement of 12 parameters: 10 fluorescence detectors, Brightfield and SSC
  • Instrument Configuration
CRTD 3rd floor south, room 3.112 0351-458-82368 You must either specify a string src or a File object. https://techpool.biotec.tu-dresden.de/schedule.php

ImageStreamX Mark II (Amnis/Millipore)

  • the Imaging Flow Cytometer combines high throughput, quantitative and sensitive single cell analysis of a Flow Cytometer with microscopic imaging and spatial resolution
  • 6 lasers: Violet (405nm), Blue (488nm), YellowGreen (561nm), Orange (592nm), Red (642nm), farRed (785nm)
  • measurement of 12 parameters: 10 fluorescence detectors, Brightfield and SSC
  • Instrument Configuration
CRTD 3rd floor south, room 3.112

MACS Technology

47 flow_cytometry autoMACS Pro Miltenyi
  • MACS Microbead Technology for magnetic cell sorting
  • walk-away cell isolation with automated labeling and separation
  • fast and gentle isolation of virtually any cell type from any species
CRTD 1st floor north, room 1.229 (1.227) 0351-458-82138 You must either specify a string src or a File object. https://techpool.biotec.tu-dresden.de/schedule.php

autoMACS Pro (Miltenyi)

  • MACS Microbead Technology for magnetic cell sorting
  • walk-away cell isolation with automated labeling and separation
  • fast and gentle isolation of virtually any cell type from any species
CRTD 1st floor north, room 1.229 (1.227)