Stem Cell Engineering - Equipment

65 es_ips Laminar Flow Hoods Herasafe™ KS ThermoFisher Scientific

The laminar flow hoods can be used for culturing human and primate iPSCs and their derivatives under biological safety levels 1 and 2 (S1 and S2).

All required plastic consumables (serological pipettes, filter tipps, reaction tubes, gloves, tissues, desinfectant, PBS) are included. The user has to bring only his own cell culture reagents (coating, medium, passaging agent, supplements) and tissue culture dishes or plates.

Genetically modified organisms have to be listed in the GVO forms of the customer lab.

Safety instruction is required for access. Please contact us for setting up an appointment.

CRTD R1.114 and R.1115 - south wing +49 351-458-82156 You must either specify a string src or a File object. https://techpool.biotec.tu-dresden.de/schedule.php?sid=32

Laminar Flow Hoods

Herasafe™ KS (ThermoFisher Scientific)

The laminar flow hoods can be used for culturing human and primate iPSCs and their derivatives under biological safety levels 1 and 2 (S1 and S2).

All required plastic consumables (serological pipettes, filter tipps, reaction tubes, gloves, tissues, desinfectant, PBS) are included. The user has to bring only his own cell culture reagents (coating, medium, passaging agent, supplements) and tissue culture dishes or plates.

Genetically modified organisms have to be listed in the GVO forms of the customer lab.

Safety instruction is required for access. Please contact us for setting up an appointment.

CRTD R1.114 and R.1115 - south wing
66 es_ips Picking Hoods Heraguard™ Eco ThermoFisher Scientific

The picking hoods can be used for manual isolation ("picking") of human and primate iPSC colonies under a stereomicroscope (Zeiss Stemi 2000-CS). For S1 work only.

All required plastic consumables (serological pipettes, filter tipps, reaction tubes, gloves, tissues, desinfectant, PBS) are included. The user has to bring only his own cell culture reagents (coating, medium, passaging agent, supplements) and tissue culture dishes or plates.

Genetically modified organisms have to be listed in the GVO forms of the customer lab.

Safety instruction is required for access. Please contact us for setting up an appointment.

CRTD R1.114 and R1.115 - south wing +49 351-458-82156 You must either specify a string src or a File object. https://techpool.biotec.tu-dresden.de/schedule.php?sid=32

Picking Hoods

Heraguard™ Eco (ThermoFisher Scientific)

The picking hoods can be used for manual isolation ("picking") of human and primate iPSC colonies under a stereomicroscope (Zeiss Stemi 2000-CS). For S1 work only.

All required plastic consumables (serological pipettes, filter tipps, reaction tubes, gloves, tissues, desinfectant, PBS) are included. The user has to bring only his own cell culture reagents (coating, medium, passaging agent, supplements) and tissue culture dishes or plates.

Genetically modified organisms have to be listed in the GVO forms of the customer lab.

Safety instruction is required for access. Please contact us for setting up an appointment.

CRTD R1.114 and R1.115 - south wing
67 es_ips Cell Culture Incubators Heracell™ 150i ThermoFisher Scientific

For incubating human and primate iPSCs and derivatives under biological safety levels 1 or 2 (S1 or S2). Standard conditons: 37°C, 5% CO2. Usage included when booking laminar flow hood and/or picking hood.

CRTD R1.114 and R1.115 - south wing +49 351-458-82156 You must either specify a string src or a File object.

Cell Culture Incubators

Heracell™ 150i (ThermoFisher Scientific)

For incubating human and primate iPSCs and derivatives under biological safety levels 1 or 2 (S1 or S2). Standard conditons: 37°C, 5% CO2. Usage included when booking laminar flow hood and/or picking hood.

CRTD R1.114 and R1.115 - south wing
68 es_ips Microscope EVOS® XL Core Microscope ThermoFisher Scientific

Cell Culture Microscope for imaging live iPSCs in culture in Phase Contrast and Bright Field mode. Saving to USB possible. Included when booking laminar flow hood and/or picking hood. Please book it seperately when using the microscope for longer time periods (no booking fees).

CRTD R1.114 - south wing +49 351-458-82156 You must either specify a string src or a File object. https://techpool.biotec.tu-dresden.de/schedule.php?sid=32

Microscope

EVOS® XL Core Microscope (ThermoFisher Scientific)

Cell Culture Microscope for imaging live iPSCs in culture in Phase Contrast and Bright Field mode. Saving to USB possible. Included when booking laminar flow hood and/or picking hood. Please book it seperately when using the microscope for longer time periods (no booking fees).

CRTD R1.114 - south wing
69 es_ips Fluorescence Microscope EVOS® FL Microscope ThermoFisher Scientific

The fluorescence microscope can be used for imaging live iPSCs in culture with EVOS LED light cubes (DAPI, GFP, RFP, Cy5) in addition to Phase Contrast and Bright Field mode. Saving to USB or server possible.

CRTD R1.115 - south wing +49 351-458-82156 You must either specify a string src or a File object.

Fluorescence Microscope

EVOS® FL Microscope (ThermoFisher Scientific)

The fluorescence microscope can be used for imaging live iPSCs in culture with EVOS LED light cubes (DAPI, GFP, RFP, Cy5) in addition to Phase Contrast and Bright Field mode. Saving to USB or server possible.

CRTD R1.115 - south wing
70 es_ips Nucleofector 4D-Nucleofector™ Core Unit + X Unit + Y Unit Lonza

For efficient electroporation of diverse cell types, cell lines and primary cells including human iPSCs as single cell solution with DNA, RNA and proteins in combination with respective Nucleofector™ kits.

CRTD R1.115 - south wing +49 351-458-82156 You must either specify a string src or a File object.

Nucleofector

4D-Nucleofector™ Core Unit + X Unit + Y Unit (Lonza)

For efficient electroporation of diverse cell types, cell lines and primary cells including human iPSCs as single cell solution with DNA, RNA and proteins in combination with respective Nucleofector™ kits.

CRTD R1.115 - south wing
71 es_ips Nanodrop NanoPhotometer® NP80 Implen

Spectrophotometer for measuring the concentration of nucleic acid and protein solutions in small volumes.

CRTD R1.115 - south wing +49 351-458-82156 You must either specify a string src or a File object.

Nanodrop

NanoPhotometer® NP80 (Implen)

Spectrophotometer for measuring the concentration of nucleic acid and protein solutions in small volumes.

CRTD R1.115 - south wing
72 es_ips Thermocycler S1000™ Thermal Cycler BIO-RAD laboratories

Thermocycler with interchangable reaction plattforms - PCRs can be performed in one 96-well plate or two 48-well plates can be run in parallel.

CRTD R1.116 - south wing +49 351-458-82156 You must either specify a string src or a File object.

Thermocycler

S1000™ Thermal Cycler (BIO-RAD laboratories)

Thermocycler with interchangable reaction plattforms - PCRs can be performed in one 96-well plate or two 48-well plates can be run in parallel.

CRTD R1.116 - south wing
73 es_ips Gel Electrophoresis System Mupid™-One NIPPON Genetics

Compact system for gel electrophoresis.

CRTD R1.116 - south wing +49 351-458-82156 You must either specify a string src or a File object.

Gel Electrophoresis System

Mupid™-One (NIPPON Genetics)

Compact system for gel electrophoresis.

CRTD R1.116 - south wing